Solid plastic
Plastic pump
Casing and wetted parts moulded from PP or PVDF. Light, economical and corrosion-free.
Acids, alkalis and other corrosive chemicals destroy ordinary metal pumps. The solution is a pump where the liquid only ever touches plastic. There are two ways to build one: a pump made entirely of plastic, or a metal pump lined with plastic. This guide explains the difference and how to choose.
A plastic pump has its casing, impeller and other wetted parts moulded from engineering plastic, usually polypropylene (PP) or PVDF. With no metal in contact with the liquid, there is nothing to corrode.
A plastic-lined pump has a metal outer casing, usually ductile iron, with a thick fluoropolymer lining such as PFA or ETFE moulded to the inside. The lining resists the chemical, while the metal shell carries the pressure and the weight of the pipework.
Solid plastic
Casing and wetted parts moulded from PP or PVDF. Light, economical and corrosion-free.
Metal shell, plastic lining
Ductile iron casing lined with PFA or ETFE. Plastic chemical resistance with the strength of metal.
| Factor | Plastic pump | Plastic-lined pump |
|---|---|---|
| Construction | Solid PP or PVDF | Metal shell lined with PFA or ETFE |
| Chemical resistance | Very good (depends on the plastic) | Excellent; fluoropolymer linings resist almost all chemicals |
| Pressure and size | Low to medium pressure, smaller flows | Higher pressure and larger flows |
| Pipe loads and impact | Lower; needs well-supported pipework | High; the metal shell takes the load |
| Weight | Light | Heavier |
| Cost | More economical | Higher than a plastic pump |
| Typical use | Chemical transfer and dosing, scrubbers, plating, high-purity liquids | Process plants, hot or aggressive acids, ANSI or ISO specified duties |
The plastic decides which chemicals and temperatures a pump can handle. As a general guide:
Plastic pumps material
Plastic pumps material
Lined pumps
Lined pumps
Always check chemical compatibility for your exact chemical, concentration and temperature, including seals and O-rings. Send us the details and we’ll check it for you.
Ductile iron magnetic drive pump with a one-piece PFA lining, 5 mm thick.
Up to 140 m³/h and 58 m head. More on M Pumps
Seal-less magnetic drive pumps in PP or PVDF.
CM MAG-P up to 40 m³/h; T MAG-P up to 60 m head.
Ductile iron mag drive pumps to ANSI dimensions, lined with ETFE, for demanding process duties.
UCR, UCP and UC Series.
Plastic magnetic drive pumps for chemical transfer, plus sealed pumps in PP or PVDF.
DB, SP, MSDB and KC/MSKC Series. FTI drum pumps
Air-operated double diaphragm pumps in PP or PVDF, with no electric motor, for hazardous and wet areas.
Various brands; 1/4″ to 2″ sizes.
Seal-less diaphragm pumps with PP or PVDF pump heads for chemical dosing and injection.
Up to 17 bar (PP) or 24 bar (PVDF), up to 60°C. More on Hydra-Cell
Fluid Prowess is a one-stop pump solution provider in Malaysia. With plastic and plastic-lined options from several brands, we recommend the right pump for your chemical, not the one we happen to stock.
A plastic pump has its casing and wetted parts moulded entirely from plastic such as polypropylene (PP) or PVDF. A plastic-lined pump has a metal outer casing, usually ductile iron, lined on the inside with a fluoropolymer such as PFA or ETFE. The liquid only touches plastic in both, but the lined pump has the strength of metal for higher pressures, larger sizes and heavier pipe loads.
Yes. Plastic and plastic-lined pumps are mainly used for corrosive chemicals such as acids, alkalis and chlorine-based solutions, which would attack metal pumps. Plastic pumps are also used for high-purity liquids in semiconductor and pharmaceutical plants, where metal contamination must be avoided.
They are closely related. PFA and PTFE are both fluoropolymers with very similar chemical resistance. PFA can be moulded into a seamless lining, so many pumps sold as PTFE-lined or Teflon-lined actually use PFA. Check the datasheet for the exact lining material.
Neither is better for every duty. Plastic pumps are lighter and more economical for low to medium pressures and moderate temperatures. Plastic-lined pumps suit higher pressures and temperatures, larger flows, hazardous areas and plants that specify metal pumps to ANSI or ISO standards.
Fluid Prowess supplies plastic and plastic-lined chemical pumps in Malaysia from M Pumps, Finish Thompson (FTI) and Wanner Hydra-Cell, plus non-metallic AODD pumps from various brands, with chemical compatibility checks and pump selection support. Contact us with your chemical and duty.
Send us the chemical, concentration, temperature, flow and pressure. We’ll recommend the right construction, material and pump.