F/M/D/H & G Series
Seal-less injection, transfer and dosing pumps covering a wide range of pressures and flows.
API 674 and API 675.
Models:
- F20/G20
- M03/G03 Mono
- M03/G03
- D04/G04
- D12/G12
- D10/G10
- D15/G15 & D17/G17
- H25/G25
- D35/G35
- D66/G66
Wanner Hydra-Cell pumps, now sold as Hydra-Cell Pro®, reach plunger-pump pressures without packing, cups or mechanical seals. Fluid Prowess supplies, sizes and supports them for plants across Malaysia, so you get a pump that doesn’t leak and a local team that knows it inside out.
A Hydra-Cell pump is a positive displacement (PD) pump that uses hydraulically balanced diaphragms instead of plungers.
Animation of a G10 pump showing how the hydraulically balanced diaphragm moves fluid without seals.
Animation of the heavy-duty T200 industrial pump and its multi-diaphragm pumping cycle.
The motor turns a drive shaft that moves a wobble plate or crankshaft. The whole mechanism runs submerged in an oil bath, away from your process fluid.
Pistons move hydraulic oil behind each diaphragm. Because the oil balances the fluid pressure, the diaphragm only ever sees a difference of about 0.21 bar (3 psi), however high the discharge pressure.
As the diaphragm pulls back, the inlet check valve opens and fluid fills the pumping chamber.
As the diaphragm pushes forward, the outlet valve opens. Up to five diaphragms fire in sequence, giving smooth, low-pulse flow.
In plunger pumps, the packing rubs against a moving plunger thousands of times a minute. In centrifugal pumps, a mechanical seal spins against the shaft. Both wear, both leak eventually, and both are the most common reason a pump comes out of service.
For maintenance teams in Malaysian plants, that usually means scheduled repacking, seal kits on the shelf, drip trays under the pump and, with hazardous fluids, an emissions and safety risk. Hydra-Cell removes that weak point entirely.
With no dynamic seals in contact with the fluid, there is no leak path and no repacking schedule.
A blocked suction line or empty tank won’t damage the pump. Wanner rates Hydra-Cell Pro to run dry indefinitely.
Handles suspended solids and abrasives up to 800 microns, and slurries up to 20,000 cP, with no seals or plungers to score.
Multiple diaphragms deliver near-continuous flow, with no pulsation dampener needed in most applications.
Flow stays constant regardless of discharge pressure and changes in step with speed, so a VFD gives precise control for dosing and metering.
High volumetric efficiency, fewer spare parts and less downtime reduce total cost of ownership.
Many models are available with ATEX explosive-zone certification for hazardous areas.
A quick comparison for engineers deciding which pump type suits a duty.
| Factor | Hydra-Cell (seal-less diaphragm) | Plunger pump | Centrifugal pump |
|---|---|---|---|
| Seals or packing | None in contact with fluid | Packing, wears regularly | Mechanical seal |
| Dry running | Tolerated | Damages packing | Damages seal |
| Abrasive fluids | Handles well | Accelerates wear | Erodes impeller and seal |
| High pressure, low flow | Well suited | Well suited | Poorly suited |
| Flow control | Linear with speed | Linear with speed | Varies with system pressure |
| Routine maintenance | Oil change, valve checks | Repacking, plunger checks | Seal and bearing checks |
Wanner’s industrial and process pumps cover flows up to 330 gpm (about 1,250 L/min) and pressures up to 5,000 psi (345 bar). Metering pumps cover up to 1,000 gph (about 3,785 L/h) and 3,500 psi (241 bar).

Seal-less injection, transfer and dosing pumps covering a wide range of pressures and flows.
API 674 and API 675.
Models:

Heavy-duty industrial and process pumps with diaphragm leak detection and containment, plus in-field serviceability.
API 674.
Models:

Metering and dosing pumps with precise, virtually pulse-free linear flow across the whole turndown range.
Meet or exceed API 675 performance standards.
Models:
We match Hydra-Cell pumps to duties where seal failure is costly, unsafe or simply a nuisance.
Fluid Prowess is a one-stop pump solution provider and an authorised distributor for Wanner Engineering in Malaysia. Buying locally means you deal with one team from selection to after-sales, in your time zone and your currency.
A seal-less pump has no packing, cups or mechanical seals in contact with the pumped fluid. In a Hydra-Cell pump, diaphragms separate the fluid from the drive end, so there is no dynamic seal to wear out or leak.
Yes. Because there are no seals that rely on the pumped fluid for lubrication or cooling, Hydra-Cell pumps can run dry without damage to the pump.
It is a hydraulically balanced diaphragm pump. It reaches pressures usually associated with plunger pumps, but without the plunger packing that needs regular replacement.
Fluid Prowess is an authorised distributor for Wanner Engineering in Malaysia and supplies Hydra-Cell pumps, spare parts and selection support. Contact us with your model number or duty.
Yes. Hydra-Cell Pro P and MT series metering pumps are used for chemical injection and dosing, such as methanol, glycol and corrosion inhibitors, and meet or exceed API 675 performance standards.
Share your fluid, flow rate, pressure and operating conditions. Our team will recommend a Hydra-Cell model, or another pump if it suits you better.